top of page

PRESSURE INSTRUMENTS

Digital Pressure Calibrators
Model PSI - DPC1, PSI - DPC 2 with different ranges options from 25 mmWC FS to
10000 PSI FS. Measurement of Differential, Gauge or Absolute Pressure.
Multiple options accuracy options from ± 0.05, ± 0.1 % of full scale range
10000 PSI FS. Measurement of Differential, Gauge or Absolute Pressure.
Multiple options accuracy options from ± 0.05, ± 0.1 % of full scale range

Digital Alarming Pressure Gauge
Model PSI - DPG1 4 Digit LED, panel mounting (DIN 96 x 96 ), ±0.5% FSD accuracy with multiple options of pressure ranges and alarm settings

Digital Barometric Pressure Indicator
Model PSI - BPI 1B, PSI - BPI-2
For Barometric or Absolute pressure measurement with ±0.25% FSD accuracy. Multiple units.
For Barometric or Absolute pressure measurement with ±0.25% FSD accuracy. Multiple units.

Pressure Calibration Hand Pumps
Models PSI-PLPG1, PSI - PP 1, PS - PP 2, PSI - PP 3L, PSI- HPP 1
Calibration accessory used for generating very low stable differential pressures to 10000 PSIG for calibrating
Magnahelic & other pressure meters. Pneumatic: Low pressure up to 30 kg/cm2 ; Hydraulic: High pressure up to 700 kg/cm2
Calibration accessory used for generating very low stable differential pressures to 10000 PSIG for calibrating
Magnahelic & other pressure meters. Pneumatic: Low pressure up to 30 kg/cm2 ; Hydraulic: High pressure up to 700 kg/cm2

Digital Pressure Meter
Model PSI – DPM2. Very Low Cost Model for various Pressure Ranges from: 100 mmWC
FS to 100 PSI FS.
FS to 100 PSI FS.
FLOW INSTRUMENTS
FLOW INSTRUMENTS

Low Flow Digital Calibrator
Model PSI - DFC1L-M and PSI-DFC1L-B Based on primary bubble detection method
and used in Gas Chromatography flow measurement and calibration of rotameters with flow rate below 500 cc/min.
and used in Gas Chromatography flow measurement and calibration of rotameters with flow rate below 500 cc/min.

Air Flow Calibrator
Model PSI - AFC 2L, PSI- AFC 2M, PSI-AFC3
Flow sensor based digital calibrator used for calibrating rotameters and other flow measuring instruments.
Multiple range options from 200 cc/min FS to 100 LPM full scale. Accuracy- 1% of reading
Flow sensor based digital calibrator used for calibrating rotameters and other flow measuring instruments.
Multiple range options from 200 cc/min FS to 100 LPM full scale. Accuracy- 1% of reading

Laminar Gas Flow Calibrator
Model PSI - LGFC-1
Based on primary laminar flow element with wide dynamic range and high accuracy. Used for calibrating rotameters
and other digital flow devices. Multiple options of ranges from 500.00 cc / min to 100.00 LPM F.S. Accuracy: 0.5% of
reading
Based on primary laminar flow element with wide dynamic range and high accuracy. Used for calibrating rotameters
and other digital flow devices. Multiple options of ranges from 500.00 cc / min to 100.00 LPM F.S. Accuracy: 0.5% of
reading

Digital Orifice Flow Calibrator
Model PSI - OFC 1, OFC -1H, PSI - OFC2, PSI - OFC3 Utilizes Orifice Flow metering
methodology. Used for calibrating Low Flow (1 lpm) to High Flow (500 lpm) FS rotameters and other instruments.
Accuracy: 1% of reading. Flow Calibration Range: 30-300 LPM (OFC1), 10-125 LPM (OFC2) & 2-30 LPM (OFC3)
methodology. Used for calibrating Low Flow (1 lpm) to High Flow (500 lpm) FS rotameters and other instruments.
Accuracy: 1% of reading. Flow Calibration Range: 30-300 LPM (OFC1), 10-125 LPM (OFC2) & 2-30 LPM (OFC3)

Electronic Gas Volume Meter
PSI - EGVM 1L, PSI - EGVM 1M, PSI - EGVM 1H
Microprocessor based electronic replacement for Dry Gas Meter. Measures flow with ±2% accuracy. Multiple range
options from 99.9 Liters to 9999.9 Liters. Each meter has two ranges with auto range selection
Microprocessor based electronic replacement for Dry Gas Meter. Measures flow with ±2% accuracy. Multiple range
options from 99.9 Liters to 9999.9 Liters. Each meter has two ranges with auto range selection

Top Loading Orifice Calibrator
Model PSI - TLOC1 & PSI - TLOC2.
Used for calibrating blower flow of HVS, RDS, PUF and PHVS Blowers. Flow Range 250 to 2500 LPM
Used for calibrating blower flow of HVS, RDS, PUF and PHVS Blowers. Flow Range 250 to 2500 LPM
TEMPERATURE AND TIME INSTRUMENTS
bottom of page